APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60
£4,697.76
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309, Metered, 0U, Three-phase, Vertical, Black, 42 AC outlet(s)
In stock
- Immediately available
- Discreet Packaging
- Free Shipping
Product Details
Description
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase els to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate f top to bottom of the PDU to facilitate better power cord management and pote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Specifications
Design
PDU types*
Metered
Type
Three-phase
Rack capacity*
0U
Mounting
Vertical
Product colour
Black
Ports & interfaces
AC outlets quantity*
42 AC outlet(s)
AC outlet types*
C13 coupler, C15 coupler, C19 coupler, C21 coupler
Features
Cable length
1.8 m
Power
Nominal input voltage*
200 - 240, 346 - 415 V
AC input frequency
50 - 60 Hz
Maximum current*
60 A
Number of phases
3
Certificates
Certification
UL 62368-1
CSA C22.2 No 62368-1
FCC part 15 subpart B
CE
EN 62368-1
Operational conditions
Operating temperature (T-T)
-5 - 60 °C
Operational conditions
Storage temperature (T-T)
-25 - 65 °C
Operating relative humidity (H-H)
5 - 95%
Storage relative humidity (H-H)
5 - 95%
Operating altitude
0 - 3048 m
Non-operating altitude
0 - 15240 m
Operating temperature (T-T)
23 - 140 °F
Weight & dimensions
Width
5.6 mm
Depth
7.5 mm
Height
182.6 mm
Weight
12.7 kg
Packaging data
Package weight
15.7 kg
Package width
132 mm
Package depth
262 mm
Package height
1980 mm
Logistics data
Total carbon footprint (kg of CO2e)
24171.76
Additional Information
| EAN/UPC | 731304439752 |
|---|---|
| MPN | APDU10450SM |
| BRAND | APC |